| Type: |
Combustion Type - Pressure Vapor
Flue Pipe - Forced Flue
Heating - Instantaneous
Source of Water - Direct Connection to Main Supply |
| Ignition |
High Voltage Discharge Spark |
| Fuel Type: |
No. 2 Fuel Oil (Typical Home Heating
Oil) or No. 1 Fuel Oil (ASTM D396)
ASTM No. 1-K Grade Kerosene or No. 1 Fuel Oil (ASTM D396)
|
| Max. Hot Water Temperature: |
155F (approximately) |
Water Flow Rate/
Temperature Rise: |
6.1 gal./min. (40F rise)
4.8 gal./min. (50F rise)
4.0 gal./min. (60F rise)
3.5 gal./min. (70F rise)
3.0 gal./min. (80F rise) |
| Capacity of Heat Exchanger: |
5.10 gal. |
| Area of Heat Transmission: |
9.7 ft.2 |
| Dimensions (W x H x D): |
12-5/8" x 27-3/4" x 22-1/2" |
| Max. Length of Vent Pipe: |
10 ft., 3 bends or less |
| Electric Rating: |
120 Volts AC, 60 Hz
Ignition - 110W
Burning - 98W |
| Required Accessories: |
Fuel Strainer, Temp. & Pressure Relief Valve |
| Nozzle: |
Quantity of Vapor - 1.1 GPH
Spraying Angle - 60 |